Chapter 2 Program Instructions
LTS& ON/OFF
Field of Application
Statement for enabling or disabling the label taken sensor.
Syntax LTS& ON|OFF
Default: LTS& OFF
Remarks
The label taken sensor (LTS) is a photoelectric device that can be tted
in the vicinity of the printers label outfeed slot and detects if a printed
label or ticket has been removed or not. (Usually, a self-adhesive label
is not fed out completely, but will remain partly stuck to the liner so
it will not fall off.)
Using the LTS ON statement, you can order the printer to stop the execution
at next PRINTFEED statement until the LTS no longer detects any label.
Then the PRINTFEED is executed. This is most useful when printing
batches of labels or tickets. As soon as a label is taken, the next one is printed
and awaits being taken care of.
The same result can also be obtained in a more cumbersome way by a
program based on the PRSTAT(2) function.
LTS& OFF revokes LTS& ON.
Example
10 LTS& ON
20 FOR A%=1 TO 5
30 B$=STR$(A%)
40 FONT "Swiss 721 BT"
50 PRPOS 200,200
60 PRTXT B$
70 PRINTFEED
80 NEXT
RUN