Intermec Fingerprint v7.61 Programmers Reference Manual Ed. 7258
Chapter 2 Program Instructions
SYSVAR, cont.
Remarks, cont.
42: Stop Media Feed in the Middle of Label Gaps
(Set or Read)
If SYSVAR(42) = 0, the media feed stops so the middle of a 3 mm (0.12
in) gap becomes aligned with the tear bar when using labels (w gaps).
This is the default setting.
If SYSVAR(42) = 1, the media feed stops so the middle of the gap becomes
aligned with the tear bar, regardless of gap size
Examples
Reading the value of a system variable, in this case the transfer ribbon
sensor:
PRINT SYSVAR(23)
Setting the value of a system variable. In this case the standard type
of Centronics is selected:
SYSVAR(25)= 0